Charging generators TR15/TR25
The HAUG charging generators Tristat TR 15 / TR 25 are high-voltage generators developed specifically for the supply of HAUG charging triodes (types ALT, ALM and ANT). The charging triode is placed at a distance of approx. 10–20 mm above the material to be charged, directly opposite the counter-eletrode. The earthed counter-electrode must be in contact with the material to be charged.
In order to achieve a continuous, operationally reliable “adhesion” of the two materials, it is important to discharge the materials to be pinned to each other before charging using a suitable HAUG ionization system.
Special features and advantages
The charging generators Tristat TR 15 and TR 25 supply an adjustable high-voltage of approx. 22 kVDC.
The units are available in either positive or negative polarity. In case of the TR 25 ,the voltage set is displayed on the integrated measuring instrument. The Tristat TR 15 / TR 25 charging generators can be pulsed using an external control.
Suitable charging triodes
HAUG charging triodes (types ALT, ALM, ANT) are characterized by a very homogenous field at the charging pins. As a result of the special geometric design of the charging triode, spark-overs to the counter-electrode are impossible. The charging triode can therefore be mounted at a distance of as little as approx. 10 mm from the material to be charged. The charging triode provides a very high charge even at low voltages and thus ensures very good adhesion.
Due to their simple design using magnetic clamps, worn charging pins can easily be exchanged. The charging triode is connected using a shielded high-voltage cable.
Branches
- Plastic processing: packaging machines, foil extruders, foil processing equipment
- Graphic industry: advanced print processing
- Glass industry: flat glass production
- Electronics industry: data carrier production
Technical data
Types | TR 15 | 230 V positive 115 V positive | Order-No.: 09.7640.000 Order-No.: 09.7641.000 |
TR 15 | 230 V negative 115 V negative | Order-No.: 09.7642.000 Order-No.: 09.7643.000 | |
TR 25 | 230 V positive 115 V positive | Order-No.: 09.7650.000 Order-No.: 09.7651.000 | |
TR 25 | 230 V negative 115 V negative | Order-No.: 09.7652.000 Order-No.: 09.7653.000 | |
Protection Type | IP 54 | ||
Protection class | I | ||
Supply voltage | 115 VAC / 230 VAC (50 – 60 Hz) | ||
Output-voltage | 22 kVDC | ||
Short-circuit output current | (lk) = 3 mA | ||
HV-terminals | 1 | ||
Power consumption | 40 VA | ||
Pulse frequency | 1 Hz pulse via floating normally open contact | ||
Operating temperature | +5 °C to +45 °C | ||
Storage/transport temperature | -15 °C to +60 °C | ||
Weight | 7 kg | ||
Mains cable | 2,6 m; fixed to the device |
Subject to technical changes!
Comparison table TR 15 / TR 25
Characteristics | TR 15 | TR 25 |
fixed pulse cable | yes | no |
Pulse socket | no | yes |
Pulse operation via floating normally open contact | yes | yes |
High-voltage display | no | yes |
Accessories
Round plug | Order-No.: X-0616 | |
Angled plug | Order-No.: X-5718 | |
Signalling cable K1 shielded | 5 m | Order-No.: 06.8941.000 |
10 m | Order-No.: 06.8941.001 | |
20 m | Order-No.: 06.8941.002 |
Download attachments: brochure operating instructions TR 15 operating instructions TR 25